Xenus Plus User Guide 16-01344 Rev 06
Copley Controls 40
2.5.3: XE2/800-1818/800-1819/800-1887 J7 Axis A/B: Drive Status Indicators
XE2/800-1818/800-1819/800-1887 J7 Axis A/B Drive Status Indicators
XE2/800-1818/800-1819/800-1887 indicator color/blink codes are described below.
Drive OK and enabled. Will run in response to reference inputs or EtherCAT commands.
Drive OK but NOT-enabled. Will run when enabled.
Positive or Negative limit switch active. Drive will only move in direction not inhibited
by limit switch.
Green flash twice
followed by a pause
STO is active, One or both STO inputs are de-energized. The drive is hardware &
software enabled but the PWM outputs cannot produce current in the motor when
STO is active.
Transient fault condition. Drive will resume operation when fault is removed.
Latching fault. Operation will not resume until fault is cleared or drive is Reset.