Xenus Plus User Guide 16-01344 Rev 06
Copley Controls 41
2.5.4: XE2/800-1818/800-1819/800-1887 J8 Network Status Indicators
XE2/800-1818/800-1819/800-1887 J8 L/A Indicators
Shows the state of the physical link and activity on the link.
L/A (Green)
Meaning
Off
No link
On
Port open, no activity
On and flickering
Port open and activity
XE2/800-1818/800-1819/800-1887 J8 RUN Indicator
Indicates the state of the ESM (EtherCAT state machine)
RUN (Green)
Meaning
Off
Init
Blinking
Pre-operational
Single flash
Safe-operational
On
Operational
XE2/800-1818/800-1819/800-1887 J8 ERR Indicator
Indicates that errors have occurred on the EtherCAT drive or network
ERR (Red)
Meaning
Off
EtherCAT communications are working correctly.
Blinking
Invalid configuration, general configuration error.
Single flash
Local error, slave has changed EtherCAT state autonomously.
Double flash
PDO or EtherCAT watchdog timeout, or an application watchdog timeout has occurred,