Xenus Plus User Guide 16-01344 Rev 06
Copley Controls 42
2.5.5: XML J6: Drive and MACRO Network Status Indicators
XML J6 STAT Indicator: Drive Status
Indicator color/blink codes are described below.
No +24 Vdc power to drive.
Drive is enabled and operational.
Drive is disabled. No faults or warnings are active.
A limit switch is active. The drive is enabled.
Green flash twice
followed by a pause
MTO is active, One or both MTO inputs are de-energized. The drive is hardware &
software enabled but the PWM outputs cannot produce current in the motor when
MTO is active.
A non-latched fault has occurred.
A latched fault has occurred.
XML J6 NET Indicator: MACRO Network Status
MACRO network has not been detected.
MACRO network detected and has disabled drive.
MACRO network detected and is trying to enable drive. This condition can occur
while the AMP LED shows any of its valid color combinations.
MACRO network errors have been detected.