EasyManua.ls Logo

Copley Controls Xenus Plus Series - Page 44

Copley Controls Xenus Plus Series
167 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Xenus Plus User Guide 16-01344 Rev 06
Copley Controls 44
2.5.7: XPL J6 STAT: Drive Status Indicator
XPL J6 STAT Indicator
XPL Drive status indicator color/blink codes are described below.
Color/Blink Code
Meaning
Not illuminated
No +24 Vdc power to drive.
Steady green
Drive is enabled and operational.
Slow-blinking green
Drive is disabled. No faults or warnings are active.
Fast-blinking green
A limit switch is active. The drive is enabled.
Green flash twice
followed by a pause
MTO is active, One or both MTO inputs are de-energized. The drive is hardware &
software enabled but the PWM outputs cannot produce current in the motor when
MTO is active.
Steady red
A non-latched fault has occurred.
Blinking red
A latched fault has occurred.