Repairs
Cornelius Deutschland GmbH
Document no. TD2005100
Version 15/03/2019, Index 0
Installation and service manual Dispensing valve
SFV1
20
6.8 Replacing the dispensing lever
6.9 Replacing the soda lever
1. Remove the soda lever, see chapter 4.4.
2. Mount the soda lever, see chapter 4.3.
Finishing tasks
1. Mount the dispensing valve, see chapter 4.1.
5. Position the new pull-type solenoid (Fig. 32/3) on the valve head (Fig. 32/2).
6. Attach the pull-type solenoid (Fig. 32/3) by pushing the pull-type solenoid (Fig. 32/3) into the
valve head (Fig. 32/2).
The pull-type solenoid must audibly engage.
7. Attach the cover (Fig. 32/1) of the pull-type solenoid (Fig. 32/3).
Finishing tasks
1. Mount the dispensing valve, see chapter 4.1.
Fig. 32
Prerequisites References
The dispensing valve has been removed. see chapter 4.2
Spare parts ID/reference Qty/amount Comment
SFV1 dosing lever: Lever (sanitary) 560003193 1
1. Remove the base plate (Fig. 33/3) of the dispensing valve by pushing the two side tabs (Fig.
33/1) apart and carefully pulling the base plate (Fig. 33/3) forwards and downwards from the
valve body (Fig. 33/2).
Fig. 33 Example graphic
2. Pull the dosing lever (Fig. 34/1) upwards out of the base plate (Fig. 34/2).
3. Insert the new dosing lever (Fig. 34/1) into the base plate (Fig. 34/2) from above.
4. Fasten the base plate (Fig. 33/3) of the dispensing valve by inserting the base plate (Fig. 33/
3) with the rear tabs into the valve body (Fig. 33/2) and carefully pushing the base plate (Fig.
33/3) upwards until the side tabs (Fig. 33/1) engage.
Finishing tasks
1. Mount the dispensing valve, see chapter 4.1.
Fig. 34 Example graphic
Prerequisites References
The dispensing valve has been removed. see chapter 4.2
Spare parts ID/reference Qty/amount Comment
Soda lever 3297 1