Viper Low overrun Service Manual
© 2016, Cornelius Inc - 9 - Publication Number: 621360241LOEWSE
Table 1 provides guidelines for machine settings based on general syrup type. Several factors, including syrup for-
mulation, level of citric acids, etc, will impact settings. These settings are to provide initial adjustments to achieve
product overruns in the 80-120% range.
NOTE: For citric syrups, adjust the CO
2 pressures down by 2-4 PSIG from the above to compensate for
the lower CO
2 adsorption.
Table 1.
Settings
Syrup Type
Set
Viscosity CO2 Setting Expansion
Nominal Settings FCB 3 50% 7 PSIG