119
Other Parameters
Setting Range
Parameter
Name
Description
IEEE1547
Rule21
Min
Default
Max
Min
Default
Max
Rule21 standard.
FaultPowerT
()
The trigger
temperature of
module ()
95.0
95.0
95.0
95.0
95.0
95.0
FaultEnvT
()
The trigger
temperature of
enviroment ()
83.0
83.0
83.0
83.0
83.0
83.0
GFCIStaticValu
e (mA)
The static
threshold value of
Leakage current
100
650
1000
100
650
1000
GFCIStaticT (s)
The static
threshold time of
Leakage current
0.00
0.20
655
0.00
0.20
655
GFCIDynProFa
ctor%
The dynamic
trigger coefficient
of Leakage current
0.0
100.0
200.0
0.0
100.0
200.0
DCIProtection1
%
Maximum DCI
value1
0.10
0.50
5.00
0.10
0.50
5.00
DCIProtectio
nT1 (s)
Trip time 1 of
DCI
0.00
60.00
120.00
0.00
60.00
120.00
DCIProtectio
n2 (mA)
Maximum DCI
value2
5
950
5000
5
950
5000
DCIProtection
T2 (s)
Trip time 2 of
DCI
0.00
1.00
120.00
0.00
1.00
120.00
PVStartVolt(
V)
PV start-up
voltage
300
330
400
300
330
400
MPPTScan
Period (s)
MPPT Scan
Cycle
300
3600
5400
300
3600
5400
ISOProtectio
n (kΩ)
Minimum
insulation
resistance
1
100
2000
1
100
2000
StarUPMinT
emp ()
The minimum
startup
-35.0
-30.0
-20.0
-35.0
-30.0
-20.0