Page 21
Option 6
Radio Key Panic Alarm to Output
- This option is used to map the operation of the Radio Key Panic
Alarm to an output i.e. when the Radio Panic is generated any output with this option enabled will turn
on.
Option 7
24 Hour Zone Alarm to Output
- This option is used to map 24 Hour Zone Alarms to an output i.e.
when the 24 Hour Zone Alarm is generated any output with this option enabled will turn on.
Option 8 24 Hour Fire Zone Alarm to Output - This option is used to map 24 Hour Fire Alarm to an output.
When the 24 Hour Fire Alarm is generated this will cause the output to flash at a rate set by the pulse
timer for this output to identify the difference between a fire alarm and normal burglar alarm.
SECONDARY ALARMS TO OUTPUT OPTIONS
P221E - P228E
In this block of addresses P221E relates to output #1, P222E relates to output #2 etc
P221E 1E Zone Tamper Alarm to Output #1
2E System Tamper Alarm to Output #1
3E Mains Failure to Output #1
4E Panel Battery Low to Output #1
5E Telephone Line Failure to Output #1
6E Dialler Failure to get a Kiss-off to Output #1
7E Automatic Pulse to Output #1
8E 24 Hour Smoke Reset to Output #1
Option 1 Zone Tampers to Output - Where dual end-of-line resistors are being used to provide individual zone
tampers this address is used to map the Zone Tampers to an output.
Option 2
System Tamper Alarm to Output
- This option is used to map activations of the common Tamper
Input to an output. This common tamper input is normally used to monitor the panel cabinet and
satellite tamper switches.
Option 3
Mails Failure To Output
- A mains failure will be indicated at the output when this option is enabled.
The Alarm Reset Timer for this output must be set to “0”.
Option 4
Panel Battery Low to Output
- A battery Low condition will be indicated at the output when this option
is enabled. The Alarm Reset Timer for this output must be set to “0”..
Option 5 Telephone Line Failure to Output - A telephone line failure will be indicated at this output when option
is enabled. When the line restores this output will return to normal.
Option 6 Dialler Failure to get a Kiss-off to Output - If the dialler reaches its maximum dialling attempts for an
alarm condition and is not kissed off, this failure will be indicated at the output. When this alarm event
is accessed via Memory Mode at any keypad the output will reset back to normal.
Option 7 Automatic Pulse to Output - This option will cause the output to pulse (at a rate set by the pulse timer
for the output) every 5 seconds. It is primarily designed to flash an external light to show that the alarm
is still active (reassurance indication).
Option 8
24 Hour Smoke Reset to Output
- This option will cause the output to pulse for 2 seconds on arming
of any Area following a 24 Hour zone alarm. It is designed to allow automatic reset of smoke detectors
following an alarm.
OUTPUT AUTO ON/OFF TIME ZONES
P231E - 238E
These addresses are used to map automatic ON and OFF periods to each of the outputs if required. When a time-
zone starts it will cause the output to turn on and when the time-zone ends it will cause the output to turn off. The
actual times assigned to each time-zone are defined at addresses P791E - P814E. Multiple Time Zones may be
assigned to each output
NOTE: A value of zero (0) at these addresses will disable any auto turn on turn off features at that output.
Out 1 Option C
1 2 - - - - - -