P231E TZE
Where TZ represents a Time-Zone # from 1-8 which defines the turn on and turn off times
required for output #1
P232E - P238E As per above but for outputs 2-8
OUTPUT INHIBIT TIME ZONES
P241E - P248E
These addresses are used to map inhibit time-zones to each of the outputs as required. The assigned time-zone
will enable the output so that it can be used during the time-zone. If an output has a time-zone assigned and that
time-zone is off, the output cannot be turned on by any programmed function (the output is inhibited). The actual
times assigned to each time-zone are defined at addresses P791E - P814E. This feature is normally used to
restrict the Access Control functions to pre-determined times and days
P241E TZE Where TZ represents the time zone which enables output #1
P242E TZE
Where TZ represents the time zone which enables output #2
P243E TZE Where TZ represents the time zone which enables output #3
P244E - P248E As per above but for outputs 4-8
NOTE: A value of zero (0) at these addresses will enable that output at all times.
PROGRAMMING KEYPAD OPTIONS
P250E - P278E
The block of addresses from P250E to P278E are used to assign the basic options of each keypad in the system.
Each of the address lines from P250E to P278E may have 8 options assigned where the 8 options represent the
individual addresses of the keypads in the system. i.e. if options 1, 2 & 4 are enabled at address P250E then
keypads 1, 2 and 4 would be assigned to area "A".
NOTE: A keypad can only be used to control the partition or area to which it has been assigned.
Within the display of the PW16 keypads you will find the indicators "A", "B" and “C”. These indicators are used to
show the Armed state of individual areas (LED on) of whether an area is in Stay Mode (LED flashing).
P250E 1-8E Keypads assigned to Area A (Default 1-8)
If the LED is On, the keypad is assigned to Area A.
P251E 1-8E Keypads assigned to Area B (Default none)
If the LED is On, the keypad is assigned to Area B.
P252E 1-8E Keypads assigned to Area C (Default none)
If the LED is On, the keypad is assigned to Area C.
P253E 1-8E Keypads with permission to fully Arm (Default 1-8)
If the LED is On, the keypad is allowed to Arm the assigned Area/s.
P254E 1-8E Keypads with permission to arm Stay Mode (Default 1-8)
If the LED is On, the keypad is allowed to Arm Stay Mode for the assigned Area/s.