P255E 1-8E
Keypads with permission to use the Control Function
(Default 1-8)
If the LED is On, the keypad can operate the “Control” function for the assigned Area/s.
P256E 1-8E
Keypads with permission to Bypass
(Default 1-8)
If the LED is On, the “Bypass” button on the keypad is enabled.
P257E 1-8E Keypads with Panic button enabled (Default 1-8)
If the LED is On, the “Panic” button on LED keypads is enabled.
P258E 1-8E Keypads with delayed Panic button enabled (Default 1-8)
If the LED is On, the “Panic” button on LED keypads must be held down for 2 seconds to create
a panic alarm. The option at address P257E MUST be off for the delayed option to work.
P259E 1-8E Keypads with Buttons 1 & 3 Panic Alarm enabled (Default 1-8)
If the LED is On, pressing buttons 1&3 simultaneously will create a Panic alarm at the keypad.
P260E 1-8E Keypads with Buttons 4 & 6 Fire Alarm enabled (Default 1-8)
If the LED is On, pressing buttons 4&6 simultaneously will create a Fire alarm at the keypad
P261E 1-8E Keypads with Buttons 7 & 9 Medical Alarm enabled (Default 1-8)
If the LED is On, pressing buttons 7&9 simultaneously will create a Medical alarm at the
keypad
P262E 1-8E Keypads with buzzer mapped to normal zone alarms
(Default 1-8)
If the LED is On, a Zone alarm during the Armed state will cause the Keypad buzzer to sound
(audible alarm) at the keypad.
P263E 1-8E Keypads with buzzer mapped to stay mode zone alarms (Default 1-8)
If the LED is On, a Stay Mode Zone alarm during the Armed state will cause the Keypad buzzer
to sound (audible alarm) at the keypad.
P264E 1-8E Keypads with buzzer mapped to 24 hour zone alarms (Default 1-8)
If the LED is On, a 24 Hour Zone alarm will cause the Keypad buzzer to sound (audible alarm) at
the keypad.
P265E 1-8E Keypads with buzzer mapped to day mode alarms (Default 1-8)
If the LED is On, a Day Zone alarm will cause the Keypad buzzer to sound (audible alarm) at the
keypad.
P266E 1-8E Keypads with buzzer mapped to armed mode exit delay beeps (Default 1-8)
If the LED is On, the keypad will sound the exit beeps when the system is armed to indicate the
exit delay has started.
P267E 1-8E Keypads with buzzer mapped to stay mode exit delay beeps (Default 1-8)
If the LED is On, the keypad will sound the exit beeps when stay mode is armed to indicate the
exit delay has started.
P268E 1-8E Keypads with buzzer mapped to entry delay beeps (Default 1-8)
If the LED is On, the keypad will sound the entry beeps to indicate the entry delay has started.
P269E 1-8E Keypad buzzer to warn of zone inactivity or supervised radio timeout alarm (Default 1-8)
If the LED is On, a Supervised Radio signal failure or no activity on a zone for the
programmed period will cause the buzzer at the keypad buzzer to sound. Pressing any button
will silence the beep.
P270E 1-8E Keypads with buzzer mapped to keypad tampers (Default 1-8)
If the LED is On, a keypad tamper alarm (four incorrect attempts to enter in a code) or a Crow
keypad tamper switch alarm will cause the buzzer at the keypad to sound.
P271E 1-8E Keypads with buzzer mapped to zone tampers (Default 1-8)
If the LED is On, a zone tamper alarm will cause the buzzer at the keypad to sound.
P272E 1-8E Keypads with buzzer mapped to system tampers (Default 1-8)
If the LED is On, a system tamper alarm will cause the buzzer at the keypad by to sound.