HIGH ZONE ASSIGNMENTS ZONES 9-16
P461E - P480E
Combinations of options in addresses P461E to P480E may be used to give the most suitable zone behaviour.
P461E 1-8E
Zone is in Area "A"
- Where options 1-8 represent zones 9-16 respectively. This option
assigns a zone to Area "A" within a partitioned system. If the system is not partitioned, all zones
must be assigned to Area "A". (Default all in Area "A") See P310E8E also.
P462E 1-8E Zone is in Area "B" - Where options 1-8 represent
zones 9-16 respectively. This option assigns a zone to
Area "B" within a partitioned system. (Default none in
Area "B") See P310E8E also.
If a zone is defined in both Area "A" and Area "B" it is deemed to be in Area "C"
P463E 1-8E Zone is a normally open input - where options 1-8 represent zones 9-16 respectively. This
option is used when normally open detectors such as smoke detectors are to connected to a
zone. The option only applies if zone doubling is turned On at P310E. Default is all zones
normally closed.
P464E 1-8E Zone is a radio detector - Where options 1-8 represent zones 9-16 respectively. This option is
used when Radio (wireless) devices are used as detectors. (Default none)
P465E 1-8E Stay Mode Zones - Where options 1-8 represent zones 9-16 respectively. Zones included at
this address will become active when the panel is in Stay Mode. Zones not assigned at this
address will be excluded. (Default 1-4) Note: Stay Mode Zones are linked to Area assignments
P466E 1-8E Zone can be Bypassed - Where options 1-8 represent zones 9-16 respectively. This option
determines if a zone can be Bypassed either manually or via the Auto-Bypass process. (Default
all on)
P467E 1-8E Auto Bypass Zones - Where options 1-8 represent zones 9-16 respectively. Zones assigned
Auto Bypass function at this address will be automatically bypassed by the system if they are
unsealed when the exit timers expire. Zones not given
Auto Bypass status will cause an activation if they are
unsealed at the end of the exit delay period. (Default all
on)
P468E 1-8E Zone is a handover - Where options 1-8 represent
zones 9-16 respectively. Zones defined at this address
as handover are given the unique ability to behave
as both delay and instant zones. If a zone defined as an
entry delay zone has been activated and the entry delay is running, a handover zone will behave
as another entry delay zone with a delay time as defined at P511E to P526E. If an entry delay
zone has not been activated and there is no entry delay running, a handover zone becomes an
instant zone with no entry delay. The Handover zone
MUST
have an entry delay programmed.
Zone is a handove
24 Hour fire zone
- - - - - - - -
- - - - - - - -