zone is unsealed (Not Ready) at the time of arming, by default the panel will Arm and the zone
will either automatically be bypassed or cause an alarm at the end of the exit delay. If the option
is turned on at this address then an unsealed condition will inhibit the panel from arming until the
zone is sealed.
PROGRAMMING DELAYS & TIMERS
ZONE ENTRY DELAY TIMES
-
P511E to P526E
P511E 0-9999E Zone 1 entry delay - 0-9999 seconds - default 20 seconds
P512E 0-9999E
Zone 2 entry delay
- 0-9999 seconds - default 20 seconds
P513E 0-9999E Zone 3 entry delay - 0-9999 seconds - default 0 (Instant)
P514E 0-9999E Zone 4 entry delay - 0-9999 seconds - default 0 (Instant)
P515E 0-9999E Zone 5 entry delay - 0-9999 seconds - default 0 (Instant)
P516E 0-9999E
Zone 6 entry delay
- 0-9999 seconds - default 0
(Instant)
P517E 0-9999E Zone 7 entry delay - 0-9999 seconds - default 0
(Instant)
P518E 0-9999E Zone 8 entry delay - 0-9999 seconds - default 0
(Instant)
P519E 0-9999E Zone 9 entry delay - 0-9999 seconds - default 0
(Instant)
P520E 0-9999E Zone 10 entry delay - 0-9999 seconds - default 0 (Instant)
P521E 0-9999E
Zone 11 entry delay
- 0-9999 seconds - default 0 (Instant)
P522E 0-9999E Zone 12 entry delay - 0-9999 seconds - default 0 (Instant)
P523E 0-9999E Zone 13 entry delay - 0-9999 seconds - default 0 (Instant)
P524E 0-9999E
Zone 14 entry delay
- 0-9999 seconds - default 0 (Instant)
P525E 0-9999E Zone 15 entry delay - 0-9999 seconds - default 0
(Instant)
P526E 0-9999E Zone 16 entry delay - 0-9999 seconds - default 0
(Instant)
AREA EXIT DELAY TIMES
-
P531E to P533E
P531E 0-999E Area "A" exit delay - 0-999 seconds - Default 60
seconds
P532E 0-999E Area "B" exit delay - 0-999 seconds - Default 60 seconds
P533E 0-999E Area "C" exit delay - 0-999 seconds - Default 60 seconds
TWO TRIGGER TIMERS
-
P534E to P536E
P534E 0-999E Area "A" Two Trigger time period - Default 60 seconds
P535E 0-999E Area "B" Two Trigger time period - Default 60 seconds
P536E 0-999E Area "C" Two Trigger time period - Default 60 seconds
STAY MODE ENTRY DELAY TIMES
-
P540E to P542E
P540E 0-999E
Area "A" Special Stay Mode entry delay
- Default 20 seconds
P541E 0-999E Area "B" Special Stay Mode entry delay - Default 20 seconds
P542E 0-999E Area "C" Special Stay Mode entry delay - Default 20 seconds
DAY ZONE TO KEYPAD BUZZER TIMES
-
P543E to P545E
P543E 1-999E Area "A" Day Zone keypad buzzer duration - Default 2 seconds
P544E 1-999E
Area "B" Day Zone keypad buzzer duration
- Default 2 seconds
P545E 1-999E Area "C" Day Zone keypad buzzer duration - Default 2 seconds
P546E 1-999E Area "A" Day Zone to Output duration - Default 2 seconds
P547E 1-999E Area "B" Day Zone to Output duration - Default 2 seconds
P548E 1-999E
Area "C" Day Zone to Output duration
- Default 2 seconds
OUTPUT RESETS TIMES
-
P551E to P558E
P551E 0-999E Output #1 reset time - Default 300 seconds (5 min)
P552E 0-999E Output #2 reset time - Default 300 seconds (5 min)
P553E 0-999E
Output #3 reset time
- Default 0 seconds (
P554E 0-999E Output #4 reset time - Default 0 seconds (
P555E 0-999E Output #5 reset time - Default 0 (latching)