USER OPTIONS
USER OPTIONS - P25E 12E (NOTE: This Option can ONLY be accessed from Client Mode)
Option 1 - Hide User Codes from Installer
Option 1 Hide User Codes from Installer - This option is only accessible from Client Program Mode. It is
designed to allow the User (owner) of the alarm to hide their User Codes from the Installer if desired.
If this option is turned On, codes can only be changed or viewed in Client program mode. Users
MUST have option 2 at location P5E assigned before they can hide the user codes.
MISCELLANEOUS USER OPTIONS - P25E 13E
Option 1 - Code Required to View Memory
Option 2 - Cancel Handover Zone Function in Stay Mode
Option 3 - Output Control from Keypad is Disabled when Armed
Option 4 - Keypad Codes are Disabled During Entry Delay
Option 5 - Keypad LEDs and Backlight off on no activity
Option 6 - Use new multi-area arming method
Option 7 - Enable Keypad Tamper Switch Alarms
Option 8 - Spare
Option 1 Code Required to View Memory - If this option is turned on, access to Memory Mode will only be
allowed by using an authorised code. The user must press <MEMORY> <CODE #> <ENTER> to
view memory events. Codes are authorised by turning on option 8 at location P4E. If this option is
turned off anyone can access memory mode.
Option 2 Cancel Handover Zone Function in Stay Mode - If this option is turned on, any zone programmed
with the handover feature will act as a normal delayed zone during Stay mode (ie the handover
feature will be ignored). The zone will still have the normal handover feature during the full arm state.
Option 3 Output Control from Keypad is Disabled when Armed - If this option is turned on any User code
programmed to operate an output for access control will be disabled when the area/s assigned (P3E)
to the user code is/are armed. If the user code is assigned to area 1 but area 2 was armed the code
can still operate the output. If no areas are assigned at P3E this option has no effect on the User
code.
Option 4 Keypad Codes are Disabled During Entry Delay - If this option is turned on no codes will operate
during the entry delay. This forces the user to disarm before entering the premises.
Option 5 Keypad LED’s and Backlight off on no activity - If this option is turned on and there is nothing
happening on the system, eg no zone activity, the LEDs on all keypads and all the backlighting will
turn off. This is particularly suited for keypads that might be mounted in a bedroom. If a zone triggers
the LEDs will turn on for 10 seconds then turn off again.
Option 6 Use new multi-area arming method - If this option is off and multiple areas are assigned to a user
the system will work in the original manner. If this option is on it will work as detailed on page 10.
Option 7 Enable Keypad Tamper Switch Alarms - If this option is turned off the panel will ignore all alarms
generated by keypad tamper switches. To enable the keypad tamper alarms this option must be
turned on.
LCD KP Idle Display Name
LCD KP Idle Display Name - P25E 14E
This location is where the LCD KP Idle Display Name can be Programmed. The Idle display name could be the
installing alarm company name, or a 24 hour call out number or what ever is deemed the best use for the Idle
message. The options that can be selected at P96E will affect whether this Idle display message is shown at the
keypad or not so refer to P96E as well.
WEBPAGE INCORRECT LOGIN COUNT
Webpage Incorrect Login Count - P25E 15E 0-255.
If this address is set to 0 there is no incorrect login count. If set from 1-255, that is the number of incorrect login
attempts before the webpage access is locked out. Using a valid code at the panel keypad to arm/disarm the