Page 73
Option 3 Blind Dial - When the dialler makes a call it looks for dial tone before making the call. If no dial tone is
detected the panel hangs up and attempts another call. The panel will do this 3 times and if dial tone is still
not detected it will make the call anyway. If blind dial is on, the panel skips the dial tone detection and dials
4 seconds after looping the line (used where non standard or low level dial tone exists).
Option 4 Use Group Numbers for Contact ID Reporting - When sending an alarm using Contact ID, the panel
can send separate account codes to report the two areas or, use one account code (P62E1E Area A) and
use the group number to identify the two areas. Turning this option on sends one account with group
numbers.
Option 5 Stay On-line after Alarm report for Audio Listen-in - If this option is turned ON and the optional listen-
in board is fitted, the panel will send a command to the monitoring company in CID or SIA formats to tell
the receiver to stay on-line so the operator can listen to the site for any sign of an intruder.
Option 6 Spare -
Option 7 Use the Dial Pre-fix Number - If the Telephone number does not provide sufficient digits for dialling
purposes it is possible to program a dial pre-fix number (P175E8E). The pre-fix can be dialled before the
telephone number. Turning this option on dials the pre-fix first followed by the telephone number.
MAXIMUM DIAL RE-TRIES per TELEPHONE NUMBER
MAXIMUM DIAL RE-TRIES per TELEPHONE NUMBER - P184E 1-8E (Value 0-99)
The maximum dial re-tries is the number of times that the panel will dial a telephone number in an attempt to get kissed
-off.
DIALLER REPORTING OPTIONS “A”
DIALLER REPORTING OPTIONS “A” - P186E 1-8E
Option 1 - Report Mains Fail
Option 2 - Report Battery Low
Option 3 - Report Radio Battery Low
Option 4 - Report Line Fail
Option 5 - Report System Tamper
Option 6 - Report Keypad Tamper
Option 7 - Report Zone Tamper
Option 8 - Report Radio Zone Tamper
Option 1 Report Mains Fail - If this option is on the panel will report a Mains fail after the report delay time
(P25E6E) has expired.
Option 2 Report Battery Low - If this option is on the panel will report a Battery Low.
Option 3 Report Radio Battery Low - If this option is on the panel will report a Battery Low from any radio zones
that have the battery status monitored.
Option 4 Report Line Fail - If this option is on the panel will report a Telephone Line fail. The panel will send the
line fail and the line restore at the same time.
Option 5 Report System Tamper - If this option is on the panel will report a Tamper Alarm on the panel tamper
input.
Option 6 Report Keypad Tamper - If this option is on the panel will report a Tamper Alarm from a keypad fitted
with a tamper switch or a wrong code alarm from a keypad.
Option 7 Report Radio Zone Tamper - If this option is on the panel will report a Radio Zone Tamper Alarm.
DIALLER REPORTING OPTIONS “B”
DIALLER REPORTING OPTIONS “B” - P187E 1-8E
Option 1 - Report Duress
Option 2 - Report Supervised Radio Alarm
Option 3 - Report Zone Inactivity Alarm