Option 4 - Report Manual Panic Alarm
Option 5 - Report Manual Fire Alarm
Option 6 - Report Manual Medical Alarm
Option 7 - Report Radio Pendant Panic Alarm
Option 8 - Report Zone Bypasses
Option 1 Report Duress - If this option is on the panel will report a Duress Alarm (see P25E2E).
Option 2 Report Supervised Radio Alarm - If this option is on the panel will report a Supervised radio Alarm
(see P25E4E).
Option 3 Report Zone Inactivity Alarm - If this option is on the panel will report a Zone Inactivity (Sensor-watch)
Alarm (see P163E).
Option 4 Report Manual Panic Alarm - If this option is on the panel will report a Keypad generated Panic Alarm.
Option 5 Report Manual Fire Alarm - If this option is on the panel will report a Keypad generated Fire Alarm.
Option 6 Report Manual Medical Alarm - If this option is on the panel will report a Keypad generated Medical
Alarm.
Option 7 Report Radio Pendant Panic Alarm - If this option is on the panel will report a Panic Alarm generated
by a radio key (pendant).
Option 8 Report Zone Bypasses - If this option is on the panel will report a Manual or Auto Bypass on a zone.
DIALLER REPORTING OPTIONS C
DIALLER REPORTING OPTIONS C - P188E 1-8E
Option 1 - Report Arm/Disarm
Option 2 - Report Stay Mode Arm/Disarm
Option 3 - Report Disarm only after an Alarm
Option 4 - Report Stay Mode Disarm only after an Alarm
Option 5 - Report Stay Mode Zone Alarms
Option 6 - Report Access to Program Mode
Option 7 - Report 24 Hour Alarms for Domestic/Voice Formats
Option 8 - Report Zone Restores
Option 1 Report Arm/Disarm - If this option is on then all Arm/Disarm signals will be reported to a Monitoring
Station if Contact ID or 4 + 2 is set as the reporting format.
Option 2 Report Stay Mode Arm/Disarm - If this option is on then all Stay Mode Arm/Disarm signals will be
reported to a Monitoring Station if Contact ID or 4 + 2 is set as the reporting format.
Option 3 Send Disarm only after an Alarm - If this option is on, the panel will not normally send an Arm/Disarm
signal to the monitoring company, however, if a zone alarm occurs then the panel will send a Disarm
following the disarming of the panel to show it has been turned off by a valid user.
Option 4 Send Stay Mode Disarm only after an Alarm - If this option is on, the panel will not normally send a
Stay Mode Arm/Disarm signal to the monitoring company, however, if a zone alarm occurs then the
panel will send a Stay Mode Disarm following the disarming of the panel to show it has been turned off
by a valid user.
Option 5 Report Stay Mode Zone Alarms - If this option is on, the panel will report zone alarms in Stay Mode.
Option 6 Report Access to Program Mode - If this option is on the panel will report a Contact ID code to indicate
that either Client or Installer program Modes have been accessed.
Option 7 Report 24 Hour Alarms for Domestic/Voice Formats - When the panel is set to send alarms via
domestic or voice mode, No alarms will normally be sent for 24 hour zones. If 24 hour alarms are
required to be reported in Domestic/Voice mode then this option must be turned on.
Option 8 Report Zone Restores - If this option is on the panel will report all zone restores in Contact ID or 4 + 2
formats. If this option is turned off the panel will only report the alarms.