Page 77
KEYPAD ADDRESS NUMBER
KEYPAD ADDRESS NUMBER - P200E 2E
This location will display the keypad number of the keypad currently in program mode.
AREAS ASSIGNED to the KEYPAD
AREAS ASSIGNED to the KEYPAD - P200E 3E
This location will display the Areas assigned to the keypad currently in program mode.
DISPLAY TIME-ZONES CURRENTLY ACTIVE
DISPLAY TIME-ZONES CURRENTLY ACTIVE - P200E 4E
This location will display which of the 32 Time-zones are currently on.
DISPLAY BATTERY VOLTAGE
DISPLAY BATTERY VOLTAGE - P200E 5E
This location will display the system battery voltage measured by the panel.
WALK TEST MODE
WALK-TEST MODE - P200E 6E
This address is used to start walk-test mode while in installer or client program mode. By pressing P200E6E at the
keypad, the keypad buzzer will beep at 1 second intervals to indicate walk-test mode is active. If a siren is
connected to an Output and that output has option 1 turned on at location P36E the siren will give a 1 second beep
every time a zone is triggered while walk-test mode is active. By walking past all of the detectors connected to the
system and activating them, the associated zone will latch up at the keypad to allow verification that all zones are
working properly. By pressing the <Program> or <Enter> button, walk-test mode will be terminated and the panel will
leave program mode. The results of the walk-test will be saved in the memory event buffer and can be viewed by
accessing memory display mode to verify which detectors were triggered during walk-test mode. If Output 1 or 2 are
used for the Audible walk-test indication and a horn speaker is connected to the output (see P37E1 or 2E option 1),
the siren on the output will give a single tone for the chirp instead of the swept tone used for alarms.
UPDATE “FIRMWARE” to LCD KP, Zone & Output EXP.
UPDATE “FIRMWARE” TO LCD KP, ZONE AND OUTPUT EXPANDERS - P200E 7E
Once a panel firmware update has been performed any new updates for the full LCD keypad, Zone or Output
expanders will transferred to the panel at the same time. By entering in P200E7E the panel will check to see if any
devices connected to the keypad bus need a firmware update and it will send those updates down the keypad bus if
required.
UPDATE “TEXT FILES” TO LCD KEYPADS
UPDATE “TEXT FILES” TO LCD KEYPADS - P200E 8E
Once a panel firmware update has been performed any new TEXT updates for the full LCD keypad will be
transferred to the panel at the same time. By entering in P200E8E the panel will send the updated text files to all LCD
keypads connected to the keypad bus.
DEFAULT CODES & TELEPHONE NUMBERS
DEFAULT CODES & TELEPHONE NUMBER - P200E 9E
This location is used to return the panels User and Installer Codes plus the Telephone Numbers & Account Codes to
the default settings.
DEFAULT ALL PROGRAMMING TO FACTORY SETTINGS
DEFAULT ALL PROGRAMMING TO FACTORY SETTINGS - P200E 10E