This location is used to return the panels programmed data (excludes any custom LCD text) back to the factory
default settings.
CLEAR ALARM MEMORY BUFFER
CLEAR ALARM MEMORY BUFFER - P200E 11E
This location is used to clear ALL of the events stored on memory.
DEFAULT ALL LCD TEXT
DEFAULT ALL LCD TEXT - P200E 12E
This location is used to return the customised LCD text back to the default values. Once defaulted at this location the
defaulted text is downloaded to all LCD keypads on the panels keypad bus.
READ RSSI from PENDANTS and WIRELESS ZONES
READ RSSI from PENDANTS and ZONES - P200E 14E
This location is used to display the RSSI (received signal strength) from Pendants and Wireless Zones that are
loaded into the panel. The feature was added at panel version V906.5 and requires the RX-16 MF receiver to be
connected to the panel for RSSI data to be available. The RSSI reading will be shown along with the user or zone
number that was received. The f
eature can only be displayed on LCD keypads with a software version of V208.5
and higher or the Icon LCD keypad
IP ALARM SETUP
PANEL IP ADDRESS - P201E 1E
This location is where the control panel IP Address can be set (provided option 1 at P201E4E is off). The IP Address
must be set to a spare IP number that matches the Local LAN IP numbering system used. The IP address set at this
location can also be viewed in normal mode by pressing the number “9” for 5 seconds.
IP GATEWAY ADDRESS - P201E 2E
This location is where the internet gateway address
can be set.
IP SUBNET MASK - P201E 3E
This is where the Subnet mask can be set. It would normally be a value of 255.255.255.0.
IP SETUP OPTIONS - P201E 4E
Option 1 - DHCP or Manual Panel IP address (Off = Automatic DHCP, On = Manual IP setting)
Option 2 - Enable logging of Ethernet resets
Option 3 - Sync panel clock
to the internet time.
Option 4 - Enable Serial ov
er IP Communications
Option 1 Manual panel IP Address - If this is On the panel must have a manually assigned IP address programmed
at P201E1E. If this option is Off DHCP will be turned on where the panel will ask for an IP and Gateway address from
the local server.
Option 2 Enable logging of Ethernet resets - If this is On the panel check
the Ethernet connection on a regular
basis and log any resets to the memory log.
Option 3 Sync Panel Clock to Internet Time - If this is On the panel the panel will update its time eve
ry 24 hours
with the programmed time server/s.
Optio
n 4 Enable Serial over IP Communications - If this option is On the RS232 BD-RUNNER 48/6 serial
commands are available as TCP/IP signals via the panels
Ethernet connection. The connection will timeout
(programmed at P25E21E) when there is no activity from the remote end via the serial over IP port. To keep the
connection alive the remote end (the automation system) wi
ll need to periodically send a signal before this timeout
value expires, eg if the timeout is set to 30 seconds the remote end should send a signal every 20 seconds. A simple
CR (Carriage return) is all that’s needed to keep the connection alive, although sending “STATUS will request the
latest panel status and keep the connection alive while providing useful information. When a session is opened with
the panel the panel will respond with “Welcome”, when the session is closed by the panel (eg this timer expires) the
panel will send “Bye.”. DISPLAY PANEL MAC ADDRESS - P201E 5E
This Address allows you to view the internal panel MAC Address. It can also be viewed by pressing the number “8”
for 5 seconds in normal mode.