Page 83
Temporary Output Disable
P25E 9E Temporary Output Disable - Output 1-32 Page 31
Miscellaneous Panel Options
P25E 10E Misc. Panel Options Miscellaneous Options Page 32
(Default = 2,6) 1 = Panel Tamper is 2k2 EOL
2 = Direct access to program mode for the installer code.
3 = Disable Mains Fail Test
4 = Globally reset trouble alarms
5 = Cannot arm the alarm if Receiver fail mode is active
6 = Enable iPSU AC and Battery Low monitoring
7 = Cannot arm if the system battery is low
8 = Installer Lockout
Installer Options
P25E 11E Installer Options Page 32
(Default = All Off) 1 = Installer MUST enter program mode via Client mode to reset confirmed alarms
2 = Installer MUST enter program mode via Client mode to reset tamper alarms
3 = Installer MUST enter program mode via Client mode to reset low battery alarms
4 = Installer MUST enter program mode via Client mode to reset supervisory alarms
5 = Cannot Arm if there is a keypad Fault
6 = Cannot Arm if there is a Telephone Line Failure or Comms Fault
7 = 10 Incorrect Code Attempts locks out the keypad for 90 Seconds
8 = User Codes Must be 4-6 digits long
User Options
P25E 12E User Options (NOTE: This Option can ONLY be accessed from Client Mode) Page 33
(Default = All Off) 1 = Hide User Codes from Installer
P25E 13E Misc. User Options Miscellaneous User Options Page 33
(Default = ) 1 = Code Required to View Memory
2 = Cancel Handover Zone Function in Stay Mode
3 = Output Control from Keypad is Disabled when Armed
4 = Keypad Codes are Disabled During Entry Delay
5 = Keypad LED’s and Backlight off on no activity
6 = Use new multi-area arming method
7 = Enable Keypad Tamper Switch Alarms
8 = Spare
LCD KP “Idle” Display Name
P25E 14E This location is where the LCD KP “Idle” Display Name can be Programmed. Page 34
Webpage “Incorrect Login” Count
P25E 15E 0-255. If this address is set to 0 there is no incorrect login count. If set from 1-255, Page 34
that is the number of incorrect login attempts before the webpage access is locked out.
Webpage “Incorrect Login” Lockout Time
P25E 16E 0-9999. If this address is set to 0 there is no lockout time if the programmed count Page 34
at P25E15E is exceeded. If set from 1-9999, that is the time in seconds that all webpage access will
be locked out for.
World Time Zone
P25E 17E World Time Zone Page 34
Program Mode/Arming Options
P25E 18E Prog/Arm Options Program Mode/Arming Options Page 34
(Default = None) 1 = Can enter program mode when another area is armed
2 = Can arm when a keypad in a different area is in program mode
3 = Serial over IP Authentication Required
8 = Hide extended information in the memory events
Serial over IP User Name
P25E 19E Serial over IP User Name (maximum 16 characters) Page 34
Serial over IP Password
P25E 20E Serial over IP Password (maximum 16 characters) Page 34
Serial over IP User Timeout
P25E 21E Serial over IP User Timeout (Default = 300, 10-600 seconds) Page 34
Setting Real Time Clock
P26E 1E Real Time Hour/Minute - Value 0-2359 Page 34
P26E 2E Real Time Day of Week - Value 1-7 (1=Sunday, 2=Monday ,etc)
P26E 3E Real Time Date/Month/Year - Value DDMMYY (eg 020904 = 2nd Sept 2004)
P26E 4E Daylight Saving is Active (If LED #1 is On, Daylight Saving is currently active) Turn this bit ON if you are in Daylight
Saving Time when the panel is installed.
NOTE: If option 3 at P201E4E is turned on (panel clock synced to the internet time) the