above time and date settings cannot be altered.
Daylight Saving settings
P27E 1E Daylight Saving Start Sunday - Value 0-5 - Default = 5 (0 = DLS disabled, 5 = last Sunday of Month) Page 34
2E Daylight Saving End Sunday - Value 0-5 - Default = 1 (0 = DLS disabled, 5 = last Sunday of Month)
P28E 1E Daylight Saving Start Month - Value 1-12 - Default = 9
2E Daylight Saving End Month - Value 1-12 - Default = 4
P29E 1E Daylight Saving Start Hour - Value 0-23 - Default = 2
2E Daylight Saving End Hour - Value 0-23 - Default = 3
+++++Outputs+++++
Bulk COPY an Output to a range of Outputs
P30E Template O/P #E Start O/P #E End O/P #E Bulk COPY an Output to a range of OUTPUTS Page 35
Program LCD KP Output Name
P31E 1-32E Program LCD KP “Output Name Text Page 35
Program Output Volume when Disarmed
P33E 1-2E The Volume of O/P 1 & 2 when the alarm is disarmed can be set to a value of 1-8 Page 35
(see P37E option 1 for details on setting O/P 1 & 2 as a siren output)
Programming Output Options “A”
P34E 1-32E Options A for Outputs 1-32 1 = Invert Output Page 35
(Default = All Off) 2 = Flash Output
3 = Single Pulse to Output
4 = Lockout Output
5 = DTMF Remote Control can operate Output
6 = User Can operate this Output
7 = “Control button Can Operate Output
8 = Chime Alarms will Flash this Output (linked to Pulse Timer)
Programming Output Options B”
P35E 1-32E Options B for Outputs 1-32 1 = Mains Fail to Output (Operates when P25E6E time expires) Page 36
(Default O/Ps 1&2 = 7) 2 = Fuse Failure to Output
(Default O/Ps 3-8 = All Off) 3 = Battery Low to output
4 = Telephone Line Failure to Output
5 = Supervised Radio Signal Failure
6 = Sensor-Watch Alarm
7 = System Tamper to Output
8 = Receiver Fail
Programming Output Options C”
P36E 1-32E Options C for Outputs 1-32 1 = Walk Test Pulse to Output Page 36
(Default = All Off) 2 = Pulse Output every 5 seconds when Disarmed
3 = Pulse Output on Kiss-off Following Arming
4 = Pulse Output on Kiss-off Following a Zone Alarm
5 = Output Disabled when P25E3E timer is running
6 = Output indicates In-coming phone call
7 = Play Doorbell tone on a Chime zone trigger
8 = IP Fail (Timed)
Programming Output Options D”
P37E 1-32E Options D for Outputs 1-32 1 = Siren Driver to Output (requires a horn speaker, outputs 1&2) Page 37
(Default = All Off) 2 = Output Chime timer is in minutes (off for -1/10th seconds)
3 = Output silenced for 10 seconds on key-press if alarm
4 = Turn Output OFF during Two Way Voice Mode
5 = Spare
6 = Pulse output when inactivity Pre-alert timer (P4072E) is running
7 = Spare
8 = Monitored Output (can tell if siren cable is cut, outputs 1&2 only)
Output ON Delay Time
P38E 1-32E Output 1-32 ON Delay Time - 0-9999 Seconds (Default = 0 Sec) Page 38
Output Pulse Time
P39E 1-32E Output 1-32 Pulse Time - 0-255;1/10th Sec increments (Default =2 which is 0.2 sec) Page 38
Output Reset Time
P40E 1-32E Output 1-32 Reset Time - 0-65535 Seconds (Default = 300 Sec) Page 38
Output Chime Mode Time
P41E 1-32E Output 1-32 Chime Timer - 0-9999;1/10th Sec increments (Default =10 which is 1 sec) Page 38
Start of Output Command Control Status Messages
P42E 1-32E Reserved for future use. Page 38
Un-Map an Output
P43E 1-32E Un-map Outputs 1-32 (remove ALL Defaults from an Output) Page 38