EasyManua.ls Logo

Crow RUNNER 8/64 - Page 86

Crow RUNNER 8/64
110 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 86
Area 1-32 Stay Mode Exit Delay Beeps to Keypad
P59E 1-32E Area 1-32 Stay Exit Delay Beeps to Keypad - Value 01-32 (for Keypads 1-32) Page 42
(Default Area 1 = All On, Areas 2-32 = All Off)
Area 1-32 Armed Exit Delay Time
P60E 1-32E Area 1-32 Exit Delay Time - Value 0-255 seconds Page 42
(Default = 30 Seconds for all Areas)
Area 1-32 Stay Armed Exit Delay Time
P61E 1-32E Area 1-32 Stay Exit Delay Time - Value 0-255 seconds Page 42
(Default = 30 Seconds for all Areas)
Area 1-32 Monitoring Account Code Number
P62E 1-32E Area 1-32 Account Code - Value 0000-FFFF Page 43
(Default = 0000 for all Areas)
Area 1-32 Remote Command Control Code Number
P63E 1-32E Area 1-32 Command Control code - Value 1-4 digit code (1-9999) Page 43
(Default = No code for all Areas)
Start Message Number for Areas 1-32 Command Control”
P64E 1-32E Reserved for future use . Page 43
Area 1-32 Armed Mode Exit Delay to Output
P65E 1-32E Area 1-32 Armed Exit Delay to Output - Value 01-32 (for Outputs 1-32) Page 43
(Default = All Off)
Area 1-32 Stay Mode Exit Delay to Output
P66E 1-32E Area 1-32 Stay Exit Delay to Output - Value 01-32 (for Outputs 1-32) Page 43
(Default = All Off)
Area 1-32 Delinquency Delay
P67E 1-32E Area 1-32 Delinquency Delay - value 0-99 Days, (0 = Off) Page 44
(Default = 0 for all Areas)
Area 1-32 Auto Arm/Disarm Time-zones
P68E 1-32E Area 1-32 Auto Arm/Disarm Time-zones - Value 01-32 (for Time-zones 1-32) Page 44
(Default = All Off)
Program LCD KP “Area Name
P69E 1-32E Program LCD KP Area Name Text Page 44
Bulk COPY an Area to a range of Areas
P70E Template Area #E Start Area #E End Area #E Bulk COPY an Area to a range of AREAS Page 44
Area 1-32 Zone Activity Timer
P4071E 1-32E Area 1-32 Zone Activity Timer - Value 0-255 Minutes
(Default = 0)
Area 1-32 Zone Activity Timer
P4072E 1-32E Area 1-32 Arming Pre-alert Timer - Value 0-255 Seconds
(Default = 0)
Area 1-32 Disarm Delay Timer
P4073E 1-32E Area 1-32 Disarm Delay Timer - Value 0-9999 Seconds
(Default = 0)
Area 1-32 In Alarm Disarm Delay Timer
P4074E 1-32E Area In Alarm Disarm Delay Timer - Value 0-9999 Seconds
(Default = 0)
+++++Keypads+++++
Keypad Area Assignment
P71E 1-32E Keypads Assigned To Areas 01-32 = Areas 1-32 Page 44
(Default = 1,2)
Keypad Button Options
P72E 1-32E Keypad Button Options 1 = <CHIME> Button Enabled Page 44
(Default = All 1,2) 2 = <BYPASS> Button Enabled
3 = Code or Tag can ARM only at this keypad
(NOTE: Options 5, 6 & 7 create a 4 = Code or Tag can STAY ARM only at this keypad
separate alarm for every area 5 = <CONTROL> + <CHIME> Panic Alarm Enabled
assigned to the keypad at P71E. 6 = <A> + <B> Fire Alarm Enabled
To clear all alarms the User MUST 7 = <B> + <CHIME> Medical Alarm Enabled
have the same areas set at P3E) 8 = Stay Armed Beep to Keypad

Related product manuals