Page 86
Area 1-32 Stay Mode Exit Delay Beeps to Keypad
P59E 1-32E Area 1-32 Stay Exit Delay Beeps to Keypad - Value 01-32 (for Keypads 1-32) Page 42
(Default Area 1 = All On, Areas 2-32 = All Off)
Area 1-32 Armed Exit Delay Time
P60E 1-32E Area 1-32 Exit Delay Time - Value 0-255 seconds Page 42
(Default = 30 Seconds for all Areas)
Area 1-32 Stay Armed Exit Delay Time
P61E 1-32E Area 1-32 Stay Exit Delay Time - Value 0-255 seconds Page 42
(Default = 30 Seconds for all Areas)
Area 1-32 Monitoring Account Code Number
P62E 1-32E Area 1-32 Account Code - Value 0000-FFFF Page 43
(Default = 0000 for all Areas)
Area 1-32 Remote “Command Control” Code Number
P63E 1-32E Area 1-32 Command Control code - Value 1-4 digit code (1-9999) Page 43
(Default = No code for all Areas)
Start Message Number for Areas 1-32 “Command Control”
P64E 1-32E Reserved for future use . Page 43
Area 1-32 Armed Mode Exit Delay to Output
P65E 1-32E Area 1-32 Armed Exit Delay to Output - Value 01-32 (for Outputs 1-32) Page 43
(Default = All Off)
Area 1-32 Stay Mode Exit Delay to Output
P66E 1-32E Area 1-32 Stay Exit Delay to Output - Value 01-32 (for Outputs 1-32) Page 43
(Default = All Off)
Area 1-32 Delinquency Delay
P67E 1-32E Area 1-32 Delinquency Delay - value 0-99 Days, (0 = Off) Page 44
(Default = 0 for all Areas)
Area 1-32 Auto Arm/Disarm Time-zones
P68E 1-32E Area 1-32 Auto Arm/Disarm Time-zones - Value 01-32 (for Time-zones 1-32) Page 44
(Default = All Off)
Program LCD KP “Area” Name
P69E 1-32E Program LCD KP “Area” Name Text Page 44
Bulk COPY an Area to a range of Areas
P70E Template Area #E Start Area #E End Area #E Bulk COPY an Area to a range of AREAS Page 44
Area 1-32 Zone Activity Timer
P4071E 1-32E Area 1-32 Zone Activity Timer - Value 0-255 Minutes
(Default = 0)
Area 1-32 Zone Activity Timer
P4072E 1-32E Area 1-32 Arming Pre-alert Timer - Value 0-255 Seconds
(Default = 0)
Area 1-32 Disarm Delay Timer
P4073E 1-32E Area 1-32 Disarm Delay Timer - Value 0-9999 Seconds
(Default = 0)
Area 1-32 “In Alarm” Disarm Delay Timer
P4074E 1-32E Area “In Alarm” Disarm Delay Timer - Value 0-9999 Seconds
(Default = 0)
+++++Keypads+++++
Keypad Area Assignment
P71E 1-32E Keypads Assigned To Areas 01-32 = Areas 1-32 Page 44
(Default = 1,2)
Keypad Button Options
P72E 1-32E Keypad Button Options 1 = <CHIME> Button Enabled Page 44
(Default = All 1,2) 2 = <BYPASS> Button Enabled
3 = Code or Tag can ARM only at this keypad
(NOTE: Options 5, 6 & 7 create a 4 = Code or Tag can STAY ARM only at this keypad
separate alarm for every area 5 = <CONTROL> + <CHIME> Panic Alarm Enabled
assigned to the keypad at P71E. 6 = <A> + <B> Fire Alarm Enabled
To clear all alarms the User MUST 7 = <B> + <CHIME> Medical Alarm Enabled
have the same areas set at P3E) 8 = Stay Armed Beep to Keypad