Page 89
Global EOL Zone Options
P119E 1E Global EOL Zone Options 0 = If set to 0 allows P125E to set individual values from 1-13 Page 53
(Default = 3) 1 = 1k
2 = 1k5
3 = 2k2
4 = 3k3
5 = 3k9
6 = 4k7
7 = 5k6
8 = 6k8
9 = 10k
10 = 12k
11 = 22k
12 = 2k2 / 4k7 (Single Zone with tamper, Series combination)
13 = 3k3 / 6k8 (Single Zone with tamper, Series combination)
14 = 2k2 / 4k7 / 8k2 (Zone doubling with tamper, Series combination)
15 = 4k7 / 8k2 (Zone doubling no tamper, Series combination)
16 = 4k7 / 8k2 (Zone doubling no tamper, Parallel combination)
Zone Key-switch Options
P120E 1-64E Zone Key-switch Options 1 = K/S can Arm Area Page 53
(Default = All Off) 2 = K/S can arm Stay Mode
3 = K/S can Disarm Area
4 = K/S can disarm Stay Mode
5 = K/S has Security Guard Options
6 = K/S will Arm Latchkey Mode
7 = Key-switch is N/O (If turned off the K/S is N/C)
8 = Key-switch is Momentary (If turned off the K/S is Latching)
Programming Zones to Areas
P121E 1-64E Assigning Zones to Areas 1-32 01-32 = Assigned to Area 1-32 Page 54
(Default = 1)
Programming Zone Options A
P122E 1-64E Programming Zone Options A 1 = Zone is Active Page 54
(Default Zone 1-4 = 1,6,7,8) 2 = Zone is N/O (Off = N/C)
(Default Zone 5-8 = 1,7,8) 3 = Not an Exit Delay Zone
(Default Zone 9-16 = 7,8) 4 = Keypad Zone
5 = Zone is a Radio Zone
6 = Zone is a Stay Mode Zone
7 = Zone can be Manually Bypassed
8 = Zone can be Auto-Bypassed
Programming Zone Options B
P123E 1-64E Programming Zone Options B 1 = Zone is a Handover Zone Page 55
(Default = All Off) 2 = Zone is a Two Trigger Zone
3 = Zone is a 24 Hour Zone
4 = Auto-reset Zone
5 = Zone is a 24 Hour Fire Zone
6 = Zone is shared (Off = not shared)
7 = Zone is a Chime Zone
8 = Zone is a Permanent Chime Zone
Programming Zone Options C
P124E 1-64E Programming Zone Options C 1 = Can Arm if Zone is not Ready Page 57
(Default = 2) 2 = Will Send Multiple Reports via Dialler
3 = Sensor-Watch Zone
4 = Zone is on Soak Test
5 = Report using the highest assigned Area
6 = Zone will Not Report 24 hour Alarms via Dialler
7 = Pulse Output on Kiss-off Following an alarm
8 = Exit Terminator
Programming Zone Options D
P6133E 1-64E Programming Zone Options D 1 = Zone is Excluded from Activity monitoring Page 57
(Default = All Off) 2 = Zone will hold off Arming until Sealed
3 = “Security Interlock” zone
Programming Zone EOL (End-of-line) Options
P125E 1-64E Programming Zone EOL Options 0 = Short Circuit Page 57
(Default = 3) 1 = 1k
(NOTE: P119E MUST be set to 0 for P125E to work) 2 = 1k5
3 = 2k2
4 = 3k3
5 = 3k9
6 = 4k7
7 = 5k6
8 = 6k8
9 = 10k
10 = 12k
11 = 22k