Control”+“Chime Panic Alarm to Outputs
P84E 1-32E Keypad Control+Chime Panic Alarm to Outputs Page 50
(Default = 1,2) 01-32 = The Keypad “Control+“Chime” Panic Alarm will turn on Output # 1-32
“A”+”B Fire Alarm to Outputs
P85E 1-32E Keypad A+B Fire Alarm to Outputs Page 50
(Default = 1,2) 01-32 = The Keypad A+B Fire Alarm will turn on Output # 1-32
B”+”Chime Medical Alarm to Outputs
P86E 1-32E Keypad B+Chime Medical Alarm to Outputs Page 50
(Default = 1,2) 01-32 = The Keypad B+”Chime” Medical Alarm will turn on Output # 1-32
Duress Alarm to Outputs
P87E 1-32E Keypad Duress Alarm to Outputs Page 50
(Default = All Off) 01-32 = The Keypad “Duress Alarm will turn on Output # 1-32
Keypad Tamper Switch” Alarm to Outputs
P88E 1-32E Keypad Tamper Switch Alarm to Outputs Page 50
(Default = All Off) 01-32 = The Keypad Tamper Switch” Alarm will turn on Output # 1-32
Keypad “Wrong Code Alarm to Outputs
P89E 1-32E Keypad “Wrong Code Alarm to Outputs Page 50
(Default = All Off) 01-32 = The Keypad Wrong Code Alarm will turn on Output # 1-32
Manually Operated Panic Alarm Beeps to Keypads
P90E 1-32E Panic Alarm Beeps to Keypads Page 51
(Default = All On) 01-32 = A Panic Alarm at the selected keypad will Beep KP # 1-32
Manually Operated Fire Alarm Beeps to Keypads
P91E 1-32E Fire Alarm Beeps to Keypads Page 51
(Default = All On) 01-32 = A Fire Alarm at the selected keypad will Beep KP # 1-32
Manually Operated Medical Alarm Beeps to Keypads
P92E 1-32E Medical Alarm Beeps to Keypads Page 51
(Default = All On) 01-32 = A Medical Alarm at the selected keypad will Beep KP # 1-32
Wrong Code or Keypad Tamper Switch Alarm Beeps to Keypads
P93E 1-32E Wrong Code or Keypad Tamper Switch Alarm Beeps to Keypads Page 51
(Default = All On) 01-32 = Wrong Code or KP Tamper at Keypad 1-32 will Beep KP # 1-32
Chime Alarm Beep Time at a Keypad
P94E 1-32E The Time the Chime Alarm will sound at Each Keypad - Value =0-255 1/10th sec Page 51
(Default = 20 which is 2 Seconds)
LCD Keypad Back-light settings
P95E 1-32E LCD Keypad Back-light Setting 0-100 = LCD B/L value 0-100% Page 51
LCD Keypad Display Options
P96E 1-32E LCD Keypad Display Options 1 = 2 x 20 Display Mode (On=AAP Logo Display) Page 51
(Default = All Off) 2 = Spare
3 = Show LCD System name (ON=Show KP Name, 1 =OFF)
4 = Display Armed Areas as numbers
5 = Spare
6 = Spare
7 = Double badge to ARM keypad
8 = Control button operates assigned outputs directly
Bulk COPY a Keypad to a range of Keypads
P97E Template KP #E Start KP #E End KP #E Bulk COPY a Keypad to a range of KEYPADS Page 52
Proximity Reader LED to Output Mapping
P98E 1-32E Proximity Reader LED to Output Mapping Page 52
(Default = None) 01-32 = Proximity Reader 1-32 LED will follow the state of Output # 1-32
Program LCD KP Keypad Name
P100E 1-32E Program LCD KP Keypad Name Text Page 52
+++++Zones+++++
Bulk COPY a Zone to a range of Zones
P118E Template Zone #E Start Zone #E End Zone #E Bulk COPY a Zone to a range of ZONES Page 53