An internal electronic fuse protects the Vecto III from over and under voltage. The
Vecto III will automatically disconnect from mains if excessive current is drawn from
the universal AC/DC supply input port. When this protection was activated, it needs a
few minutes to cool, during which the Vecto III will not restart even with valid mains
voltage.
During a power interruption/failure, the internal battery will power the device for ± 30
minutes. When the battery charge drops below 50% of full capacity, the device will
gracefully shut down to protect the battery from being damaged.
When power is restored, the device will automatically restart within 15 seconds if the
battery status is above 30% or first recharge until the battery reach 30% and only then
restart.
Figure 8: Ethernet ports
IEEE 802.3-2008 compliant Power over Ethernet (PoE) Plus is available on both
Ethernet ports at 48 V. The PoE capability enables the Vecto III to be powered through
the communication infrastructure. The Vecto III will therefore be continuously
available if the communication infrastructure remains active.