EasyManua.ls Logo

D-Link DGS-1510/ME Series - Page 209

D-Link DGS-1510/ME Series
654 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DGS-1510/ME Series Metro Ethernet Switch CLI Reference Guide
205
DGS-1510-28XMP/ME:admin# config ddm trap enable
Command: config ddm trap enable
Success.
DGS-1510-28XMP/ME:admin#
22-2 config ddm ports
Description
The command is used to configure the DDM settings of the specified ports.
Format
config ddm ports [<portlist> | all] [[temperature_threshold | voltage_threshold | bias_current_threshold |
tx_power_threshold | rx_power_threshold] {high_alarm <float> | low_alarm <float> | high_warning <float> |
low_warning <float>} | {state [enable | disable] | shutdown [alarm | warning | none]}]
Parameters
<portlist> - Enter the range of ports to be configured here.
all - Specifies that all the optic ports’ operating parameters will be configured.
temperature_threshold - Specifies the threshold of the optic module’s temperature in centigrade. At least one
parameter shall be specified for this threshold.
voltage_threshold - Specifies the threshold of optic module’s voltage.
bias_current_threshold - Specifies the threshold of the optic module’s bias current.
tx_power_threshold - Specifies the threshold of the optic module’s output power.
rx_power_threshold - Specifies the threshold of optic module’s received power.
high_alarm - (Optional) Specifies the high threshold for the alarm. When the operating parameter rises above
this value, the action associated with the alarm is taken.
<float> - Enter the high threshold alarm value used here.
low_alarm - (Optional) Specifies the low threshold for the alarm. When the operating parameter falls below this
value, the action associated with the alarm is taken.
<float> - Enter the low threshold alarm value used here.
high_warning - (Optional) Specifies the high threshold for the warning. When the operating parameter rises
above this value, the action associated with the warning is taken.
<float> - Enter the high threshold warning value here.
low_warning - (Optional) Specifies the low threshold for the warning. When the operating parameter falls below
this value, the action associated with the warning is taken.
<float> - Enter the low threshold warning value here.
state - (Optional) Specifies the DDM state to enable or disable. If the state is disabled, no DDM action will take
effect.
enable - Specifies to enable the DDM state.
disable - Specifies to disable the DDM state.
shutdown - (Optional) Specifies whether or not to shut down the port when the operating parameter exceeds the
corresponding alarm threshold or warning threshold. The default value is none.
alarm - Shutdown the port when the configured alarm threshold range is exceeded.
warning - Shutdown the port when the configured warning threshold range is exceeded.