Example 2.13. Interface ping test between all interfaces
selftest -ping
Example 2.14. Interface ping test between interfaces 'if1' and 'if2'
selftest -ping -interfaces=if1,if2
Example 2.15. Start a 30 min burn-in duration test, testing RAM, storage media and
crypto the accelerator
selftest -burnin -minutes 30 -media -memory -cryptoaccel
Usage
selftest -memory [-num=<Integer>]
Check the sanity of the RAM.
selftest -media [-size=<Integer>]
Check the sanity of the disk drive.
selftest -mac
Check if there are MAC address collisions on the interfaces.
selftest -ping [-interfaces=<Interface>]
Run a ping test over the interfaces.
selftest -throughput [-interfaces=<Interface>]
Run a throughput test over the interfaces.
selftest -traffic [-interfaces=<Interface>]
Run a traffic test over the interfaces.
selftest -cryptoaccel
Verify the correct functioning of the accelerator cards.
selftest -burnin [-hours[=<Integer>]] [-minutes[=<Integer>]]
[-memory] [-media] [-ping] [-throughput] [-traffic]
[-cryptoaccel]