IPC oine alarm: When the network connection between the NVR and the network
camera is o, the system performs alarm linkage actions.
Figure 5-207 Local alarm
Step 3 Click Setting next to Schedule to congure the alarm schedule.
Step 4 Congure the anti-dither period.
If multiple alarms occur during the anti-dither period, the system only record the event
once.
Step 5 Congure alarm linkage. For details, see Table 5-50 .
Step 6 Enable Disarming so that you can connect a switch to the alarm input port for disarming
control.
Step 7 Click Apply.
5.10.4 Alarm Output
Background Information
You can set proper alarm output mode to auto, manual or o. After you connect the alarm device
to the alarm output port of NVR, and set the mode to auto, the system performs alarm linkage
actions when an alarm occurs.
Auto: Once an alarm event occurs, the system generates an alarm.
Manual: Alarm device is always on the alarming mode.
O: Disable alarm output function.
Procedure
Step 1 Select Main Menu > ALARM > Alarm-out Port.
User's Manual