EasyManuals Logo

Daikin SUPER MULTI NX G Series Service Manual

Daikin SUPER MULTI NX G Series
285 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #242 background imageLoading...
Page #242 background image
SiUS12-928_B Outdoor Unit: 3MXS24JVJU, 4MXS32GVJU
Removal Procedure 234
2.2 Removal of Electrical Box
Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure Points
1
Remove the 2 screws to
detach the ground wires.
2
Disconnect the connector
for the fan motor [S70].
3
Release the fan motor
lead wire.
: When reassembling, do not
use these 2 hooks.
(R10396)
[S70]
(R10397)
(R17268)
Fan motor lead wire

Table of Contents