0-51 Set-up Copy
Option: Function:
[0]
*
No copy No function
[1] Copy to set-up 1 Copies all parameters in the present edit set-up (defined in par.
0-11
Edit Set-up
) to Set-up 1.
[2] Copy to set-up 2 Copies all parameters in the present edit set-up (defined in par.
0-11
Edit Set-up
) to Set-up 2.
[3] Copy to set-up 3 Copies all parameters in the present edit set-up (defined in par.
0-11
Edit Set-up
) to Set-up 3.
[4] Copy to set-up 4 Copies all parameters in the present edit set-up (defined in par.
0-11
Edit Set-up
) to Set-up 4.
[9] Copy to all Copies the parameters in the present set-up over to each of the
set-ups 1 to 4.
2.3.8. 0-6* Password
Define password access to menus.
0-60 Main Menu Password
Option: Function:
[100]
*
-9999 - 9999 Define the password for access to the Main Menu via the [Main
Menu] key. If par. 0-61
Access to Main Menu w/o Password
is
set to
Full access
[0], this parameter will be ignored.
0-61 Access to Main Menu w/o Password
Option: Function:
[0]
*
Full access Disables password defined in par. 0-60
Main Menu Password
.
[1] Read only Prevent unauthorized editing of Main Menu parameters.
[2] No access Prevent unauthorized viewing and editing of Main Menu param-
eters.
[3] Bus: Read only Read only functions for parameters on fieldbus and/ or FC
standard bus.
[4] Bus: No access No access to parameters is allowed via fieldbus and/ or FC
standard bus.
[5] All: Read only Read only function for parameters on LCP, fieldbus or FC stand-
ard bus.
[6] All: No access No access from LCP, fieldbus or FC standard bus is allowed.
If
Full access
[0] is selected then parameters
0-60, 0-65 and 0-66 will be ignored.
0-65 Quick Menu Password
Range: Function:
200
*
[-9999 - 9999] Define the password for access to the Quick Menu via the [Quick
Menu] key. If par. 0-66
Access to Quick Menu w/o Password
is
FC 300 Programming Guide 2. How to Programme
MG.33.M2.02 - VLT
®
is a registered Danfoss trademark
41
2