9-70 Programming Set-up
This parameter is unique for LCP and eldbus. See
parameter 0-11 Programming Set-up.
Option: Function:
Select the set-up to be edited.
[0] Factory setup Uses default data. This option can be used
as a data source to return the other set-ups
to a known state.
[1] Set-up 1 Edits Set-up 1.
[2] Set-up 2 Edits Set-up 2.
[3] Set-up 3 Edits Set-up 3.
[4] Set-up 4 Edits Set-up 4.
[9] * Active Set-up
Follows the active set-up selected in
parameter 0-10 Active Set-up.
9-71 Probus Save Data Values
Option: Function:
Parameter values changed via PROFIBUS are not
automatically stored in non-volatile memory.
Use this parameter to activate a function that
stores parameter values in the EEPROM non-
volatile memory, so changed parameter values
are retained at power-down.
[0] * O Deactivates the non-volatile storage function.
[1] Store all
setups
Stores all parameter values for all set-ups in the
non-volatile memory. When all parameter values
have been stored, the selection returns to [0]
O.
[2] Store all
setups
Stores all parameter values for all set-ups in the
non-volatile memory. When all parameter values
have been stored, the selection returns to [0]
O.
9-72 ProbusDriveReset
Option: Function:
[0] * No action
[1] Power-on
reset
Resets the frequency converter upon power-up,
as for power-cycle.
[3] Comm
option
reset
Resets the PROFIBUS option only, useful after
changing certain settings in parameter group
9-** Probus, for example, parameter 9-18 Node
Address.
When reset, the frequency converter
disappears from the
eldbus, which may cause
a communication error from the master.
9-80 Dened Parameters (1)
Array [116]
No LCP access
Read only
Range: Function:
0* [0 - 9999 ] This parameter displays a list of all the dened
frequency converter parameters available for
PROFIBUS.
9-81 Dened Parameters (2)
Array [116]
No LCP access
Read only
Range: Function:
0* [0 - 9999 ] This parameter displays a list of all the dened
frequency converter parameters available for
PROFIBUS.
9-82 Dened Parameters (3)
Array [116]
No LCP access
Read only
Range: Function:
0* [0 - 9999 ] This parameter displays a list of all the dened
frequency converter parameters available for
PROFIBUS.
9-83 Dened Parameters (4)
Array [116]
No LCP access
Read only
Range: Function:
0* [0 - 9999 ] This parameter displays a list of all the dened
frequency converter parameters available for
PROFIBUS.
9-90 Changed Parameters (1)
Array [116]
No LCP access
Read only
Range: Function:
0* [0 - 9999 ] This parameter displays a list of all the
frequency converter parameters deviating from
default setting.
9-91 Changed Parameters (2)
Array [116]
No LCP access
Read only
Range: Function:
0* [0 - 9999 ] This parameter displays a list of all the
frequency converter parameters deviating from
default setting.