Procedure for EMC Jumper 1, MR9A
1. Remove the cover of the fan.
2. In IP54, also remove the fan.
3. Loosen the screws of the cover plate and remove it.
e30bh375.10
4. Find the place of the jumper behind the fan. Remove the EMC jumper.
e30bh376.10
5. Attach the cover plate.
6. In IP54, attach the fan.
7. Attach the cover of the fan.
8. After the change, write "The EMC level was changed" and the date on the "product modified" label. If the label is not yet attached,
attach it on the drive near the nameplate.
e30bg773.10