PNU # Parameter description Factory setting 4-set-up Conv. index Data type
600 Operating hours No 73 7
601 Hours run No 73 7
602 kWh counter No 2 7
603 Number of cut ins No 0 6
604 Number of overtemperatures No 0 6
605 Number of overvoltages No 0 6
615 Fault log: Error code No 0 5
616 Fault log: Time No 0 7
617 Fault log: Value No 0 3
618 Reset of kWh counter No reset No 0 7
619 Reset of running hours counter No reset No 0 5
620 Operation mode Normal operation No 0 5
621 Nameplate: Unit type No 0 9
624 Nameplate: Software version No 0 9
625 Nameplate: LCP identification no. No 0 9
626 Nameplate: Database identification no. No -2 9
627 Nameplate: Power parts version No 0 9
628 Nameplate: Application option type No 0 9
630 Nameplate: Communication option type No 0 9
632 Nameplate: BMC software identification No 0 9
634 Nameplate: Unit identification for communication No 0 9
635 Nameplate: Software parts no. No 0 9
640 Software version No -2 6
641 BMC software identification No -2 6
642 Power card identification No -2 6
678 Configure control card
700
Used for wobble function. See the Wobble
Function Instruction for more details.
Table 5.24 Factory Settings for Parameters 600-700
4-Set-up
Yes means that the parameter can be programmed
individually in each of the 4 set-ups, i.e. one single
parameter can have 4 different data values. No means that
the data value is the same in all set-ups.
Conversion index
This number refers to a conversion factor to be used when
writing or reading via serial communication with a
frequency converter.
See chapter 4.7.4 Data Character (Byte) for further
information.
Data type
Data type shows the type and length of the telegram.
Data type Description
3 Integer 16
4 Integer 32
5 Unsigned 8
6 Unsigned 16
7 Unsigned 32
9 Text string
Table 5.25
All about VLT 2800 Design Guide
154 Danfoss A/S © Rev. May/2014 All rights reserved. MG27E402
55

Table of Contents

Other manuals for Danfoss VLT 2800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT 2800 and is the answer not in the manual?

Danfoss VLT 2800 Specifications

General IconGeneral
Frequency50/60 Hz
EnclosureIP20
Input Voltage200-240V AC
Output Power Range0.37-2.2kW
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short Circuit
Communication InterfaceRS485
Operating Temperature-10°C to +40°C
Storage Temperature-25°C to +65 °C
Relative Humidity5 - 95% RH, non-condensing
Output Voltage0 - 100% of supply voltage

Related product manuals