146 Reset voltage vector
Value:
*Off (OFF) [0]
Reset (RESET) [1]
Function:
When the voltage vector is reset it is set to the same
starting point each time a new process commences.
Description of choice:
Select [1] Reset when running unique processes each time
they arise. This enables repetitive precision when stopping
to be improved. Select [0] Off for example for lifting/
lowering operations or synchronous motors. It is an
advantage that the motor and the frequency converter are
always synchronised.