Type designation
P18K
P22K
P30K
P37K
P45K
Protection ratings IP21, IP55, IP66
maximum cable cross-section for
brake, and load sharing [mm2
(AWG)]
50 (1)
50 (1)
50 (1)
95 (3/0)
95 (3/0)
Maximum cable cross-section
(3)
for
disconnect [mm
2
(AWG)]
50, 35, 35 (1, 2, 2)
95, 70, 70 (3/0, 2/0, 2/0)
185, 150, 120
(350 MCM, 300 MCM,
4/0)
Estimated power loss
(4)
at rated
maximum load [W]
(5)
625
737
740
845
874
1140
1143
1353
1400
1636
Eciency
(6)
0.96
0.97
0.97
0.97
0.97
1
High overload=150% or 160% torque for a duration of 60 s. Normal overload=110% torque for a duration of 60 s.
2
Enclosure sizes B3+B4 and C3+C4 can be converted to IP21 using a conversion kit. See also chapters Mechanical mounting and IP21/Type 1 Enclo-
sure kit in the design guide.
3
The 3 values for the maximum cable cross-section are for single core, exible wire, and exible wire with sleeve, respectively.
4
Applies for dimensioning of drive cooling. If the switching frequency is higher than the default setting, the power losses may increase. LCP and
typical control card power consumptions are included. For more detailed eciency values and part load losses according IEC/EN 61800-9-2 refer to
mydrive ecosmart on
www. danfoss.com. For eciency class see 8.4.1 Environment.
5
Eciency measured at nominal current. For more detailed eciency values and part load losses according IEC/EN 61800-9-2 refer to mydrive ecos-
mart on
www. danfoss.com. For eciency class see 8.4.1 Environment.
6
Measured using 5 m (16 ft) shielded motor cables at rated load and rated frequency. For more detailed eciency values and part load losses ac-
cording IEC/EN 61800-9-2 refer to mydrive ecosmart on
www. danfoss.com. For eciency class see 8.4.1 Environment.
8.1.3 Mains Supply 1x380–480 V AC
Table 30: Mains Supply 1x380–480 V AC, Normal Overload 110% for 1 Minute, P7K5–P37K
Type desig nation
P7K5
P11K
P18K
P37K
Typical shaft output [kW]
7.5
11
18.5
37
Typical shaft output at 240 V [hp]
10
15
25
50
Protection rating IP21/Type 1
B1
B2
C1
C2
Protection rating IP55/Type 12
B1
B2
C1
C2
Protection rating IP66/NEMA 4X
B1
B2
C1
C2
Output current
Continuous (3x380–440 V) [A]
16
24
37.5
73
Intermittent (3x380–440 V) [A]
17.6
26.4
41.2
80.3
Continuous (3x441–480 V) [A]
14.5
21
34
65
Intermittent (3x441–480 V) [A]
15.4
23.1
37.4
71.5
Continuous kVA at 400 V [kVA]
11
16.6
26
50.6
Continuous kVA at 460 V [kVA]
11.6
16.7
27.1
51.8
Maximum input current
Continuous (1x380–440 V) [A]
33
48
78
151
Intermittent (1x380–440 V) [A]
36
53
85.5
166
AJ300847815559en-000101 / 130R033776 | Danfoss A/S © 2020.09
Specications
VLT® AQUA Drive FC 202
Design Guide

Table of Contents

Other manuals for Danfoss VLT AQUA FC 202

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AQUA FC 202 and is the answer not in the manual?

Danfoss VLT AQUA FC 202 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AQUA FC 202
CategoryDC Drives
LanguageEnglish

Related product manuals