M,N
Rated motor frequency (nameplate data).
I
M
Motor current (actual).
I
M,N
Nominal motor current (nameplate data).
n
M,N
Nominal motor speed (nameplate data).
n
s
Synchronous motor speed.
n
s
=
2 × Parameter 123 × 60s
Parameter 139
n
slip
Motor slip.
P
M,N
Rated motor power (nameplate data in kW or hp).
T
M,N
Rated torque (motor).
U
M
Instantaneous motor voltage.
U
M,N
Rated motor voltage (nameplate data).
Break-away torque
e75za078.10
(1)
(2)
(3)
Illustration 82: Break-away Torque
1
Torque
2
RPM
3
Pull-out
η
VLT
The efficiency of the drive is defined as the ratio between the power output and the power input.
Start-disable command
A start-disable command belonging to the control commands in group 1. See the table in chapter Input for more details.
Stop command
A stop command belonging to the control commands in group 1. See the table in chapter Input for more details.
AJ363928382091en-000101 / 130R0983140 | Danfoss A/S © 2021.04
Appendix
VLT® Flow Drive FC 111
Design Guide

Table of Contents

Other manuals for Danfoss VLT Flow Drive FC 111

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT Flow Drive FC 111 and is the answer not in the manual?

Danfoss VLT Flow Drive FC 111 Specifications

General IconGeneral
BrandDanfoss
ModelVLT Flow Drive FC 111
CategoryDC Drives
LanguageEnglish

Related product manuals