EasyManua.ls Logo

Danfoss VLT Flow Drive FC 111 - 5 Mechanical Installation Considerations; 5.1 Power Ratings, Weights, and Dimensions

Danfoss VLT Flow Drive FC 111
148 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 Mechanical Installation Considerations
5.1 Power Ratings, Weights, and Dimensions
e
f
a
e
e
f
a
d
e
A
a
b
B
C
D
e30bf984.10
Illustration 40: Dimensions, Enclosure Sizes H1–H8
Table 31: Power Ratings, Weights, and Dimensions, Enclosure Sizes H1–H4
Enclosure Size
H1
H2
H3
H4
IP class
IP20
IP20
IP20
IP20
Power [kW (hp)]
3x380–480 V
0.37–1.5
(0.5–2.0)
2.2–4.0
(3.0–5.0)
5.5–7.5
(7.5–10)
11–15
(15–20)
Height [mm (in)]
A
195 (7.7)
227 (8.9)
255 (10.0)
296 (11.7)
A
(1)
273 (10.7)
303 (11.9)
329 (13.0)
359 (14.1)
a
183 (7.2)
212 (8.3)
240 (9.4)
275 (10.8)
Width [mm (in)]
B
75 (3.0)
90 (3.5)
100 (3.9)
135 (5.3)
b
56 (2.2)
65 (2.6)
74 (2.9)
105 (4.1)
Depth [mm (in)]
C
168 (6.6)
190 (7.5)
206 (8.1)
241 (9.5)
Mounting hole [mm (in)]
d
9 (0.35)
11 (0.43)
11 (0.43)
12.6 (0.50)
e
4.5 (0.18)
5.5 (0.22)
5.5 (0.22)
7 (0.28)
f
5.3 (0.21)
7.4 (0.29)
8.1 (0.32)
8.4 (0.33)
Maximum weight kg (lb)
2.1 (4.6)
3.4 (7.5)
4.5 (9.9)
7.9 (17.4)
1
Including decoupling plate.
Table 32: Power Ratings, Weights, and Dimensions H6–H8
Enclosure Size
H5
H6
H7
H8
IP class
IP20
IP20
IP20
IP20
Power [kW (hp)]
3x380–480 V
18.5–22
(25–30)
30–45
(40–60)
55–75
(70–100)
90 (125)
Height [mm (in)]
A
334 (13.1)
518 (20.4)
550 (21.7)
660 (26)
A
(1)
402 (15.8)
595 (23.4)/635 (25), 45 kW
630 (24.8)/690 (27.2), 75 kW
800 (31.5)
AJ363928382091en-000101 / 130R0983 | 53Danfoss A/S © 2021.04
Mechanical Installation
Considerations
VLT® Flow Drive FC 111
Design Guide

Table of Contents

Other manuals for Danfoss VLT Flow Drive FC 111

Related product manuals