Cable length [m (ft)]
AC line voltage [V]
Rise time [μsec]
V
peak
[kV]
dU/dt [kV/μsec]
50 (164)
400
0.340
1.056
2.517
400 V 0.75 kW (1.0 hp)
5 (16)
400
0.160
0.808
4.050
25 (82)
400
0.240
1.026
3.420
50 (164)
400
0.340
1.056
2.517
400 V 1.5 kW (2.0 hp)
5 (16)
400
0.160
0.808
4.050
25 (82)
400
0.240
1.026
3.420
50 (164)
400
0.340
1.056
2.517
400 V 2.2 kW (3.0 hp)
5 (16)
400
0.190
0.760
3.200
25 (82)
400
0.293
1.026
2.801
50 (164)
400
0.422
1.040
1.971
400 V 3.0 kW (4.0 hp)
5 (16)
400
0.190
0.760
3.200
25 (82)
400
0.293
1.026
2.801
50 (164)
400
0.422
1.040
1.971
400 V 4.0 kW (5.4 hp)
5 (16)
400
0.190
0.760
3.200
25 (82)
400
0.293
1.026
2.801
50 (164)
400
0.422
1.040
1.971
400 V 5.5 kW (7.4 hp)
5 (16)
400
0.168
0.81
3.857
25 (82)
400
0.239
1.026
3.434
50 (164)
400
0.328
1.05
2.560
400 V 7.5 kW (10 hp)
5 (16)
400
0.168
0.81
3.857
25 (82)
400
0.239
1.026
3.434
50 (164)
400
0.328
1.05
2.560
400 V 11 kW (15 hp)
5 (16)
400
0.116
0.69
4.871
25 (82)
400
0.204
0.985
3.799
50 (164)
400
0.316
1.01
2.563
400 V 15 kW (20 hp)
5 (16)
400
0.139
0.864
4.955
50 (82)
400
0.338
1.008
2.365
400 V 18.5 kW (25 hp)
5 (16)
400
0.132
0.88
5.220
25 (82)
400
0.172
1.026
4.772
50 (164)
400
0.222
1.00
3.603
400 V 22 kW (30 hp)
5 (16)
400
0.132
0.88
5.220
25 (82)
400
0.172
1.026
4.772
AJ363928382091en-000101 / 130R098378 | Danfoss A/S © 2021.04