RS-232 Parameters
Product Reference Guide
275
NAK Character
This setting specifies an ASCII character or hex value to be used as the NAK
character. ASCII characters or any hex value from 0 to 0xFF can be selected.
Setting to previously defined characters such as XON, XOFF, or
host commands conflicts with normal operation of these char-
acters. 8-bit data is not recognized when the option
Data Bits
has been set as 7 Data Bits.
To set this feature:
1. Determine the desired character or value.
2. Use the ASCII Chart on the inside back cover of
this manual to find the
hex equivalent for the desired character/value.
3. Go to page 52 and scan the ENTER/EXIT PROGRAMMING MODE bar code
to enter Programming Mode.
4. Scan the bar code: SELECT NAK
CHARACTER SETTING.
5. Scan the appropriate two alphanumeric
characters from the keypad in
Appendix D, Keypad, that represent the desired c
haracter/value in step
1 above. The second character wil
l cause a two-beep indication.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Program-
ming Mode.
This completes the procedure. See Table 27 for some examples of how to
set this feature.
Table 27. NAK Character Setting Examples
STEP ACTION EXAMPLES
1 Desired Character/Value
NAK $ @ >
2
Hex equivalent from
ASCII
Chart
0x15 0x24 0x40 0x3E
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT NAK CHARACTER SETTING
5
Scan Two Characters From
Appendix D, Keypad
‘1’ and ‘5’ ‘2’ and ‘4’ ‘4’ and ‘0’ ‘3’ AND ‘E’
6 Scan ENTER/EXIT PROGRAMMING MODE

Table of Contents

Other manuals for Datalogic Gryphon I GD4400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Gryphon I GD4400 and is the answer not in the manual?

Datalogic Gryphon I GD4400 Specifications

General IconGeneral
Environmental SealingIP52
Dimensions18.1 x 7.1 x 10.0 cm / 7.1 x 2.8 x 3.9 in
Connectivity TechnologyWired
Operating Temperature0 to 50 °C / 32 to 122 °F
Storage Temperature-20 to 70 °C / -4 to 158 °F
Ambient Light Immunity0 to 100, 000 lux
ESD Protection16 kV
InterfaceUSB, RS-232, Keyboard Wedge, IBM 46XX
Resolution4 mils
Drop ResistanceWithstands drops from 1.8 m / 5.9 ft to concrete
Weight195 g / 6.88 oz
Decode Capability1D Codes, 2D Codes, Postal Codes, Stacked Codes
Scan RateUp to 60 frames per second