EasyManuals Logo

Datalogic PM9300 User Manual

Datalogic PM9300
332 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #170 background imageLoading...
Page #170 background image
Enter/Exit Programming Mode
160
PowerScan™ PD9330/PBT9300/PM9300
GS1 DataBar™ Omnidirectional Minimum Reads
This setting has no effect for AR models.
This feature specifies the minimum number of consecutive times a GS1
Dat
aBar Omnidirectional label must be decoded before it is accepted as
good read.
DEFAULT
GS1 DataBar Omnidirectional Minimum Reads = 1
GS1 DataBar Omnidirectional Minimum Reads = 2
GS1 DataBar Omnidirectional Minimum Reads = 3
GS1 DataBar Omnidirectional Minimum Reads = 4

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PM9300 and is the answer not in the manual?

Datalogic PM9300 Specifications

General IconGeneral
BrandDatalogic
ModelPM9300
CategoryBarcode Reader
LanguageEnglish

Related product manuals