Enter/Exit Programming Mode
84
PowerScan™ PD9330/PBT9300/PM9300
GTIN FORMATTING
This feature enables/disables the ability to convert UPC-E, UPC-A, and EAN
13 labels into the GTIN 14-character format.
DEFAULT
$CGBEN00(CR)
GTIN Formatting = Disable
$CGBEN01(CR)
GTIN Formatting = Enable
If add-on information is present on the base label prior to the
conversion taking place, the add-on information will be
appended to the converted GTIN label.
EAN 13 (JAN 13)
The following options apply to the EAN 13 (Jan 13) symbology.
EAN 13 Enable/Disable
When disabled, the reader will not read EAN 13/JAN 13 bar codes.
$C3BEN00(CR)
EAN 13 = Disable
$C3BEN01(CR)
EAN 13 = Enable
DEFAULT