Enter/Exit Programming Mode
88
PowerScan™ PD9330/PBT9300/PM9300
EAN 8 to EAN 13
Enable this option to expand EAN 8/JAN 8 labels to EAN 13/Jan 13.
DEFAULT
Expand EAN 8 to EAN 13 = Disable
Expand EAN 8 to EAN 13 = Enable
EAN 8 Minimum Reads
This setting has no effect for AR models.
This feature specifies the minimum number of consecutive times an EAN 8
(Jan
8) label must be decoded before it is accepted as good read.
DEFAULT
EAN 8 Minimum Reads = 1
EAN 8 Minimum Reads = 2
EAN 8 Minimum Reads = 3
EAN 8 Minimum Reads = 4