EasyManuals Logo

Datalogic PM9300 User Manual

Datalogic PM9300
332 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #172 background imageLoading...
Page #172 background image
Enter/Exit Programming Mode
162
PowerScan™ PD9330/PBT9300/PM9300
GS1 DataBar™ Expanded Minimum Reads
This setting has no effect for AR models.
This feature specifies the minimum number of consecutive times a GS1
DataBar Exp
anded label must be decoded before it is accepted as good read.
DEFAULT
GS1 DataBar Expanded Minimum Reads = 1
GS1 DataBar Expanded Minimum Reads = 2
GS1 DataBar Expanded Minimum Reads = 3
GS1 DataBar Expanded Minimum Reads = 4
GS1 DataBar™ Expanded Length Control
This feature specifies either variable length decoding or fixed length decod-
ing for the GS1 DataBar™ Expanded symbology.
Variable Length:
For variable-length decoding, a minimum length may be set.
Fixed Length:
For fixed-length decoding, two different lengths may be set.
DEFAULT
$
GS1 DataBar™ Expanded Length Control =
Variable Length
GS1 DataBar™ Expanded Length Control = Fixed Length

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PM9300 and is the answer not in the manual?

Datalogic PM9300 Specifications

General IconGeneral
BrandDatalogic
ModelPM9300
CategoryBarcode Reader
LanguageEnglish

Related product manuals