Enter/Exit Programming Mode
72
PowerScan™ PD9330/PBT9300/PM9300
Scanning Active Time
This setting specifies the amount of time that the reader stays in scan ON
state once the state is entered. The range for this setting is from 1 to 255
seconds in 1-second increments. See page 277 in “References” for further
description of this feature.
$CSNET03(CR)
Scanning Active Time = 3 seconds
$CSNET05(CR)
Scanning Active Time = 5 seconds
DEFAULT
$CSNET08(CR)
Scanning Active Time = 8 seconds
Flash On Time
This feature specifies the ON time for the indicator LED while in Flash Mode.
The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in
100 millisecond increments. See page 278 in “References” for detailed infor-
mation on setting this feature.
$CSNFN
Select Flash ON Time Setting
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu-
meric characters in
Appendix D, Keypad
repre-
senting your desired character(s). End by scanning
the
ENTER/EXIT bar code twice.
Make a mistake? Scan the CANCEL
bar code to abort
and not save the entry string. You can then start
again at the beginning.
~
CANCEL
DEFAULT
10 = Flash is ON for 1 Second

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PM9300 and is the answer not in the manual?

Datalogic PM9300 Specifications

General IconGeneral
BrandDatalogic
ModelPM9300
CategoryBarcode Reader
LanguageEnglish

Related product manuals