EasyManuals Logo

Datamax MP Compact4 Mark II Programmer's Manual

Datamax MP Compact4 Mark II
330 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #105 background imageLoading...
Page #105 background image
Extended System-Level Command Functions
Class Series 2 Programmer’s Manual 93
(SA) SOP Adjust – This command sets the start of print (SOP) location, relative to
the top of form. See <STX>O for command details. The EX2 accepts this command for
backward compatibility only, limited in range (28-228).
(SC) Scalable CacheThis command sets the number of 1K blocks allocated for
the scaleable font engine. Available memory dependent upon model; see Appendix
K. (For non-display models see the <STX>KS command.)
(SE) SOP Emulation – This command enables the <STX>O and <STX>f print
positioning commands to allow backward compatibility with label formats designed
for other printers.
(SF) Save As Filename – This command, which may be sent separately or included
as the last command in an <STX>Kc command string, saves the effective printer
configuration to a file in Flash memory with a .dcm file extension.
(SG) Sensor Gain Value – This command sets the control of the voltage to the LED
emitter of the Media Sensor.
(SH) Scalable Heap – This command sets a working “scratch pad space” in DRAM
for scalable font construction.

Table of Contents

Other manuals for Datamax MP Compact4 Mark II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datamax MP Compact4 Mark II and is the answer not in the manual?

Datamax MP Compact4 Mark II Specifications

General IconGeneral
BrandDatamax
ModelMP Compact4 Mark II
CategoryPrinter
LanguageEnglish

Related product manuals