STX M Set Maximum Label Length
This command instructs the printer move media this distance in search of the top-of-
form (label edge, notch, black mark, etc.) before declaring a paper fault. A paper fault
condition can occur if this setting is too close (within 0.1 inch [2.54 mm]) to the physical
length of the label. Therefore, it is a good practice to set this command to 2.5 to 3 times
the actual label length used. The minimum value should be at least 5” (127 mm).
Syntax:
<STX>Mnnnn
Where:
nnnn -
Is a four-digit length, 0000-9999, in/100 or mm/10.
Maximum setting is 9999 (99.99 inches or 2540
mm). The default setting is 16 inches/ 406.4 mm.
Sample:
<STX>M0500
The sample above sets a maximum travel distance of 5 inches
(unless the printer is in metric mode; see <STX>m).
STX m Set Printer to Metric Mode
This command sets the printer to interpret measurements as metric values (e.g.,
<STX>c0100 will equal 10.0 mm). The default is Imperial (see <STX>n).
Syntax:
<STX>m
STX n Set Printer to Imperial Mode
This command sets the printer to interpret measurements as inch values (e.g.,
<STX>c0100 will equal 1.00 inch), and is the default mode.
Syntax:
<STX>n

Table of Contents

Other manuals for Datamax MP Compact4 Mark II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datamax MP Compact4 Mark II and is the answer not in the manual?

Datamax MP Compact4 Mark II Specifications

General IconGeneral
BrandDatamax
ModelMP Compact4 Mark II
CategoryPrinter
LanguageEnglish

Related product manuals