Extended System-Level Command Functions
Class Series 2 Programmer’s Manual 109
STX KO GPIO Output
This command configures the GPIO outputs of the Applicator Interface Card; see
Appendix J for details.
Syntax:
<STX>KOffnsptd0pw0td1pw1<CR>
ff
- 2 character function name abbreviation (e.g., LC [Label
Complete], LM [Label Movement], etc).
n
- Pin number, where 1 – 8 is the valid range.
s
- Signal type, where: L = Level; P = Positive Pulse; and N
= Negative Pulse
p
- Polarity, where: 0 = Active Low; and 1 = Active High
td0
- 3 character delay time from function condition “true” to
output signal.
pw0
- 3 character pulse width corresponding to the function
condition becoming “true”. (Ignored for level-type
signals.)
td0
- 3 character delay time from function condition “false” to
output signal.
Where:
pw0
- 3 character pulse width corresponding to the function
condition becoming “false”. (Ignored for level-type
signals.)