Class Series 2 Programmer’s Manual 11
3
Immediate Command Functions
Introduction
When the printer receives an Immediate Command, its current operation will be
momentarily interrupted to respond to the command. Immediate Commands may be issued
before or after System-Level commands; however, they may not be issued among Label
Formatting Commands or during font or image downloading. Immediate Commands consist
of:
1. Attention-Getter, 0x01 or 0x5E; see Control Code Command Functions.
2. Command Character
SOH # Reset
This command resets the printer. Resetting the printer returns all settings to default and
clears both the communications and printing buffers. The command also clears DRAM
memory.
Syntax:
<SOH>#
Printer Response: The printer will reset.
<XON> T
(The T may come before the <XON>)
SOH * Reset (Display-Equipped Models only)
This command forces a soft reset of the microprocessor, resetting the printer, returning
all factory default values, and clearing the communication and print buffers.
Syntax:
<SOH>*
Printer Response: The printer will reset.
<XON> R
(The R may come before the <XON>)

Table of Contents

Other manuals for Datamax MP Compact4 Mark II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datamax MP Compact4 Mark II and is the answer not in the manual?

Datamax MP Compact4 Mark II Specifications

General IconGeneral
BrandDatamax
ModelMP Compact4 Mark II
CategoryPrinter
LanguageEnglish

Related product manuals