Extended System-Level Command Functions
110 Class Series 2 Programmer’s Manual
STX Kp Module Protection
This command controls memory module protection. When “protected”, a module will
ignore format, downloads and delete commands. This command can be useful to add
data to reserved modules (see Appendix K for a listing of the memory modules). There
are two module types: RAM (volatile) and Flash (non-volatile).
RAM - When protected and if power is cycled or if the printer is reset, the module
state resets to unprotected.
Flash - When protected, the module can be temporarily unprotected; however, if
power is cycled or if the printer is reset, the module state resets to protected.
Syntax:
<STX>Kpmf
m
-
Module ID – Range A to Z (See Appendix K).
Where:
f
-
Flag specifying Enable or Disable protection, where:
0 = disable protection; and,
1 = enable protection.
Sample:
<STX>KpY0
The sample above disables protection for Module Y; graphics may
now be downloaded to the module and, on subsequent resets,
these graphics will be protected.

Table of Contents

Other manuals for Datamax MP Compact4 Mark II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datamax MP Compact4 Mark II and is the answer not in the manual?

Datamax MP Compact4 Mark II Specifications

General IconGeneral
BrandDatamax
ModelMP Compact4 Mark II
CategoryPrinter
LanguageEnglish

Related product manuals