Extended System-Level Command Functions
120 Class Series 2 Programmer’s Manual
STX KuB Read Data from Gen2 Tag Section
This command reads a specific block address of a Gen2 tag.
Syntax:
<STX>KuBaaabbb
aaa
-
Block address number, where: 000 is kill/access
section; 001 is EPC section; 002 is Tag ID; and, 003 is
user memory.
Where:
bbb
-
Data offset in word length.
Sample:
<STX>KuB001002
The sample above reads the block address 1 at offset word 2,
which is location of the EPC data.
STX KuF Send RFID Device Firmware Version
This command instructs the RFID device to return the firmware version.
Syntax:
<STX>KuF<CR>
Printer response:
DEVICE VERSION: XXX.XXX.XXX[CR]
STX KuJ Write Data to Gen 2 Tag Section
This command writes a specific block address of a Gen2 tag.
Syntax:
<STX>KuJaaabbb<data>
aaa
-
Block address number, where: 000 is kill/access
section; 001 is EPC section; 002 is Tag ID; or, 003 is
user memory.
bbb
-
Data offset in word length
Where:
<data>
-
Hexadecimal data (must be length of multiples of 4)
Sample:
<STX>KuJ001002112233445566778899AABBCC
The sample above writes data “112233445566778899AABBCC” to
block address 1 at offset word 2, which is the EPC data.

Table of Contents

Other manuals for Datamax MP Compact4 Mark II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datamax MP Compact4 Mark II and is the answer not in the manual?

Datamax MP Compact4 Mark II Specifications

General IconGeneral
BrandDatamax
ModelMP Compact4 Mark II
CategoryPrinter
LanguageEnglish

Related product manuals