Extended System-Level Command Functions
54 Class Series 2 Programmer’s Manual
<STX>Kc
Parameter Name
Parameter
Pneumonic
Value /
Range
Units /
Interpretation
Menu Item (or Number)
(if available)
Command
Equivalent
Paper Empty
PO
0 – 9999 1/100 inch Media Settings N/A
Paper Value
PV
0 – 255 N/A Media Settings N/A
Parallel Direction
PP
xz See Table 5-7. Communications N/A
Password Set
PW
A – Z,
0 – 9
Four characters
(or, if security is
enabled then eight
characters).
System Settings N/A
Pause Mode
PM
Y, N
Y = Enabled,
N = Disabled
System Settings
<STX>J
Peel Mode
PE
Y, N
Y = Enabled,
N = Disabled
System Settings N/A
(continued)