Extended System-Level Command Functions
56 Class Series 2 Programmer’s Manual
<STX>Kc
Parameter Name
Parameter
Pneumonic
Value /
Range
Units /
Interpretation
Menu Item (or Number)
(if available)
Command
Equivalent
Print Speed
pS
Alpha character
Model specific
ranges; see
Appendix L.
Print Control
Pa
Query Configuration
QQ
Q, K N/A Configuration Label N/A
Reflective Paper Value
RV
0 – 255 N/A Media Settings N/A
Retract Delay
RW
1 – 255
Specified value times
ten milliseconds
Printer Options N/A
Rewinder Adjust
RR
-xx, +yy
Applied torque,
where -30 to +15 is
the valid range.
Printer Options N/A
Rewinder Equipped
RM
A/Y, E, N/D
A or Y = Auto,
E = Enabled,
N or D = Disabled
Printer Options N/A
RFID Configuration
RI
A, B, D, E, L, M, N,
P, R, S, T, U, V, W
See Table 5-8. Printer Options N/A
Ribbon Low Diameter
RL
100 – 200 1/100 in. Media Settings N/A
(continued)